| Retail Fireworks Permit Inspection List |
|

Please use the following checklist as a guide to obtain a Collin
County Retail Fireworks Stand Permit. These are some of the items
we will check for upon inspection.
NOTE: 28TAC 34.817(a) states, "It
is the responsibility of the supervisor to comply with the fireworks rules".
EXTERIOR
- Sell <100' from storage & dispensing
of flammables.
Sec 17(f2)
- Adequate off road parking provided.
34.817(1)
- NO SMOKING signs at least 4" letters,
posted.
34.917(g)
- Trash or cardboard boxes within 10' of stand.
38.817(m)
- High grass/weeds within 10' of stand.
34.817(m)
- Suitable lock to prevent unauthorized entry
when closed.
38.818(d)
- Electrical service installed in accordance
to NEC & AHJ.
38.818(b3)
INTERIOR
- Egress clear.
34.817(e)
- Correct number of egress doors (>16' two doors).
- 34.818(a)
- Egress doors open outward and unlocked when stand opened.
34.817(d)
INTERIOR ELECTRICAL
- Main disconnect.
38.818(b2)
- Drop cords and extension cords being used.
34.818(b4)
- Electrical installation in accordance with NEC and AHJ.
34.818(b3)
- Heat or light source with open flames.
38.818(c)
- Current "Green Tag" (see Development Services for information)
GENERAL
- Permit for each retail stand not connected.
34.817(j)
- Operator at least 16YOA on duty.
34.817(g)
- Smoking inside or within 10' of stand.
34.817(g)
- Operator consuming or under influence of alcohol.
34.817(g)
- Fireworks sold or offered to children under 12 YOA.
Sec. 17(d)
GENERATOR
- Generator at least 10' from stand.
34.818(b5)
- High grass, weeds, trash near generator.
34.818(b5)
- 6 BC extinguisher on site for generator.
34.818(b5)
STRUCTURE
- Selling from single/multifamily structure.
34.817(k)
- Selling fireworks from tent or motor vehicle.
34.817(f)
FIREWORKS
- Sell illegal fireworks e.g. bottle rockets,
M-80's. Sec 2(b)
- Fireworks do not conform to USCPS Labeling.
34.817(o)
- Fireworks being discharged <100' from fireworks stand
- Displayed fireworks within reach of customer
|